Magnalocks are designed to
secure any kind of door or gate that closes against a fixed stop.
The product consists of an electromagnet which mounts on the fixed
frame, and a strike plate which mounts on the moving door or gate.
The strike plate is delivered with fasteners that let it flex, so
when a door closes, it automatically self-aligns with the magnet.
Powerful magnetic force then secures the door, and release is
achieved by switching off current.
Magnalocks are remarkably
efficient. Model 32 draws only 3-1/2 watts. Model 62 draws only 3
watts. Models 34 and 82SC draw only 4 watts. Low power consumption
is especially important when large numbers of Magnalocks are
operated from a central power supply. Efficiency saves in wire
gauge, power supply and battery backup costs. Advanced internal
electronics eliminate problems found in other designs. Magnalocks
reverse out residual magnetism and accelerate field collapse, so
that inductive kickback and EMI are suppressed. There is no arcing
over control switches, or interference with nearby electronics.
Ferrous metal aging— which can lead to stickiness—is blocked. A
U.S. patent has been granted on the Magnalock’s internal
electronics.
Model 62
Applications
Model 62 increases holding
power to 1,200 pounds, appropriate for exterior and perimeter
doors through which criminals could gain entrance to cause
substantial economic loss. Entry cannot be forced without special
tools, or before the door and frame actually give way. Model 62 is
also available with the “G” option, which adds a universal conduit
fitting for outdoor installations or surface-wired installations
on concrete filled door frames.
• All ferrous metal surfaces
plated to MIL specification
• Hardware accessories
available to configure any opening type include mounting brackets,
housings and dress covers
• Ten feet [3.05m] of
jacketed, stranded conductor
• Automatic dual voltage—no
field adjustment required
• UL Listed
Magnalocks Technical
data
Holding Force
• 62 Series: 1,200 lbs. - 545
Kg.
Operating
Environment
140 to 60 C, -40 to 140 F.
Suitable for outdoor use (NEMA 4X equivalent). A ferrous metal
surfaces plated in MIL spec. Magnet case: brushed stainless steel
standard.
Power Required
• 62 Series: 250 mA at 12
VDC or 125 mA at 24 VDC
Voltage tolerance: -10% +30%,
unregulated acceptable.
Dimensions
• Strike: 10" x 2-3/4" x
½" (254 x 70 x 12mm)
• Model 62 Magnet: 8" x 3" x
1-3/4" (203 x 76 x 44.5mm)
• Strike: 6" x 2-3/4" x
½" (152 x 70 x 12mm)
• Model 34 Magnet: 9-3/4" x
1-3/4" x 1-1/8" (241 x 38 x 28.5mm)
• Model 34R Magnet: 9-1/2" x
1-1/2" x 1-1/8" (241 x 38 x 28.5mm)
• Strike: 6-3/8" x 1-7/16" x
7/16" (162 x 36.5 x 11mm)
• Model 32 Magnet: 8" x
1-3/4" x 1-1/2" (203 x 44.5 x 38mm)
• Strike: 6-1/2" x 1-5/8" x
½" (165 x 41.5 x 12mm)
Approvals &
Lisdtings
• Underwriter's
Laboratories: SA6635 and BP7041 and R13976
• Underwriter's laboratories
and Canada: CMS140, SA6635 and BP7041